Henry Ford Hospital Detroit Varian Medical Systems Edge Radiosurgery Suite

Henry Ford Hospital in Detroit was the first in North America and the only hospital in Michigan to have the Edge Radiosurgery Suite.


October 14, 2014 — A new stereotactic radiosurgery system provides the same or a higher level of accuracy in targeting cancer tumors — but offers greater comfort to patients and the ability to treat multiple tumors at once — when compared to other radiation therapy stereotactic systems, according to researchers at Henry Ford Hospital in Detroit.

The study shows the Edge Radiosurgery Suite is able to target cancer tumors within 1 mm, providing sub-millimeter accuracy with extreme precision.

“Radiosurgery is just one shot of precision radiation with a very high dose to treat tumors,” says study lead author Ning Wen, Ph.D., a physicist with the department of radiation oncology at Henry Ford.

“The key is targeting the tumor and delivering the dose that we want while protecting surrounding normal tissue, which is why it is so important to regularly evaluate the systematic accuracy of such systems.”

The study as presented at the 56th annual American Society for Radiation Oncology (ASTRO) meeting in San Francisco.

Stereotactic radiation is a procedure that precisely delivers intense radiation doses to tumor targets in one to five treatments. The goal of this non-invasive procedure is to destroy, or make inactive, the tumor while minimizing dose exposure to the surrounding healthy tissue.

The Edge, created by Varian Medical Systems, is the latest advancement in stereotactic radiosurgery. It offers treatment in about 20 minutes and uses new real-time tumor tracking technology to help compensate for tumor motion during treatment. Its six degrees of freedom treatment couch provides flexibility needed to optimally position and adjust patients, allowing them to be comfortable and breathe freely during treatment.

Henry Ford was the first in North America and it is the only hospital in Michigan to have the Edge.

“The Edge truly represents a novel platform in radiosurgery, offering a system that provides a fully-integrated solution for planning and administering radiosurgery treatments,” notes Benjamin Movsas, M.D., chair of the department of radiation oncology at Henry Ford and a co-author of the study.

For its study, Henry Ford sought to evaluate the accuracy of the Edge by comparing it to existing robot- or frame-based radiosurgery systems.

To do so, researchers took a novel approach using — for the first time — a phantom prototype cube to determine treatment precision.

The phantom includes implanted inserts and has four different densities for cone beam computed tomography, three Calypso beacons, 5 mm diameter steel BBs in the center for localization accuracy testing, 16 ceramic BBs for radiographic imaging, and simultaneous dual orthogonal film planes insert for dosimetric verification.

With the phantom prototype, targets were localized using all components of the Edge system, including optical surface monitoring system, electromagnetic beacon-based tracking, cone-beam computed tomography (CT), “snap-shot” planar x-ray imaging during treatment and a “robotic” six-degree of freedom couch.

Ten plans were created to study various treatment sites including brain, spine, lung and pancreas.

Overall, the study demonstrated that the “end-to-end” locational accuracy of the Edge was within 0.9 mm for single target treatment and 1.2 mm for single isocenter multi-targets treatment, making it highly accurate when compared to robot- or frame-based radiosurgery systems.

“With our radiosurgery team, everything we do is continuously under study,” says Wen. “As pioneers in the field, we want to show we have done due diligence with this new system to ensure we’re providing the best care to our patients.”

Wen and his colleagues plan to continue to study the Edge, expanding their research to evaluation how tumors interact with treatment.

Along with Drs. Wen and Movsas, Henry Ford study co-authors are Haisen Li, Ph.D.; Kang Song, Karen Chin Snyder, Jinkoo Kim, Hualiang Zhong, James Gordon, Ph.D.; Indrin Chetty, Ph.D.; Salim Siddiqui, M.D.; Farzan Siddiqui, M.D.; Munther Ajlouni, M.D.; and Samuel Ryu, M.D.

Research support for this study was provided by Varian and Henry Ford Hospital.

For more information: www.henryford.com


Related Content

News | Radiation Dose Management

April 25, 2024 — BIOTRONIK, a leading global medical technology company specializing in innovative cardiovascular and ...

Time April 25, 2024
arrow
News | Artificial Intelligence

March 28, 2024 — As artificial intelligence (AI) makes its way into cancer care – and into discussions between ...

Time March 28, 2024
arrow
News | Prostate Cancer

March 27, 2024 — A minimally invasive treatment using MRI and transurethral ultrasound instead of surgery or radiation ...

Time March 27, 2024
arrow
Videos | Radiation Oncology

In the conclusion of this 3-part video series on recent advancements in diagnostic radiology, current editorial advisory ...

Time March 19, 2024
arrow
News | Breast Imaging

March 18, 2024 — QT Imaging Holdings, Inc., a medical device company engaged in research, development, and ...

Time March 18, 2024
arrow
Feature | Radiation Oncology | By Christine Book

Appreciating the considerable advances in the clinical application of artificial intelligence (AI) within healthcare ...

Time March 06, 2024
arrow
News | FDA

March 1, 2024 — Varian, a Siemens Healthineers company, announced that it has received 510(k) clearance from the U.S ...

Time March 01, 2024
arrow
News | Breast Imaging

February 22, 2024 — The FAST-Forward randomized trial from the UK found that ultrahypofractionated whole breast ...

Time February 22, 2024
arrow
News | Radiation Oncology

February 22, 2024 — The National Institutes of Health has launched a clinical trials network to evaluate emerging ...

Time February 22, 2024
arrow
News | Radiation Oncology

February 14, 2024 — Accuray Incorporated announced that the team at Quebec’s Montérégie Integrated Cancer Center, part ...

Time February 14, 2024
arrow
Subscribe Now