Technology | September 22, 2008

Head and Neck Phantom Supports Radiation Oncology QA

Fluke Biomedical’s Model 74-001 IMRT phantom is designed to address commissioning and comparison of treatment planning systems and verification of individual patient plans and delivery.

Circular in shape, the phantom is approximately the size of an average patient, and is made from unique proprietary materials that reportedly mimic bone and water within 1 percent from 50 keV to 25 MeV, enabling thorough analysis of both the treatment planning and delivery systems.

Tissue equivalent interchangeable rod inserts for ionization chambers allow for point dose measurements in multiple planes in the phantom and film calibration. The phantom also supports film dosimetry with not only standard radiographic films but also GAFCHROMIC media. Optional inserts are available to support a variety of other detectors including TLD’s, MOSFET and diodes.

The 74-001 accommodates one Ready Pack 10x12 inch film in transverse orientation, two radiochromic or radiographic 10 cm x 10 cm films in transverse orientation and/or a stack or thirteen radiochromic pre-cut to 63.5 mm x 63.5 mm in three different orientations.

Five different electron density reference plugs can be interchanged in five separate locations within the phantom. The surface of the phantom is etched with grooves to ensure proper orientation of the CT slices and accurate film to plan registration. An optional cranial bone ring is also available.

Related Content

RaySafe Introduces Pro-Slit Camera for Accurate Focal Spot Measurement
Technology | Digital Radiography (DR) | June 27, 2017
Unfors RaySafe recently introduced the RaySafe Pro-Slit Phantom and the RaySafe Pro-Stand.
IBA Dosimetry Americas Announces New Exclusive Canadian Distributor for Radiotherapy Products
News | Radiation Therapy | April 28, 2017
April 28, 2017 — IBA (Ion Beam Applications S.A.) announced the Dosimetry Americas division has recently partnered wi
Medsquare, VirtualDose CT module, organ dose calculation, DACS Radiation Dose Monitor, RDM
Technology | Radiation Dose Management | March 24, 2017
Medsquare announced the integration of the organ dose module VirtualDose CT into its DACS (dose archive and...
Konica Minolta, AeroDR wireless flat panel detectors, AeroRemote Monitoring Service, digital radiography, RSNA 2017
Technology | Digital Radiography (DR) | March 10, 2017
Konica Minolta HealthcareAmericas Inc. recently announced the launch of itsAeroRemote cloud-based, active monitoring...
IBA, Dolphin Online Ready Patient QA and Monitoring solution, radiotherapy, North West Cancer Centre, Londonderry, Northern Ireland, first in U.K.
News | Radiation Therapy | February 07, 2017
IBA (Ion Beam Applications S.A.) recently announced the first clinical implementation of its Dolphin Online Ready...
Virtual Phantoms, Qaelum, radiation dose monitoring, organ dose data
News | Quality Assurance (QA) | January 16, 2017
January 16, 2017 — Qaelum NV announced recently that they have entered into a partnership to bring the VirtualDose co
Technology | Quality Assurance (QA) | January 10, 2017
January 10, 2017 — Mobius Medical Systems LP announced in December that DoseLab, the complete TG-142 solution, now fu
SPECT-CT, 3-D printing, University of Wurzburg, Germany, Johannes Tran-Gia, dosimetry calibration

SPECT/CT reconstructions and VOIs used for determination of calibration factors for the adult kidney filled with Lu-177 (A) and the corresponding sphere filled with I-131 (B). Credit: University of Würzburg

News | 3-D Printing | January 06, 2017
In nuclear medicine, the goal is to keep radiation exposure at a minimum, while obtaining quality images. Optimal...
Sponsored Content | Videos | Quality Assurance (QA) | December 20, 2016
Learn more about myQA, IBA’s unique platform that connects QA applications, people, and know-how through a central...
Multidata Systems International Corp, water phantom, FDA warning
Feature | Radiation Therapy | October 21, 2016 | Dave Fornell
October 21, 2016 — The U.S.
Overlay Init