News | Artificial Intelligence | September 18, 2023

AI system by Lunit identified improperly positioned endotracheal tube on chest radiographs obtained after insertion, as well as on chest radiographs obtained from patients in the ICU at two institutions

AI system by Lunit identified improperly positioned endotracheal tube on chest radiographs obtained after insertion, as well as on chest radiographs obtained from patients in the ICU at two institutions

Left: Chest radiograph from 80-year-old patient in sample A. AI identified endotracheal tube (ETT) with probability score of 0.98, and properly localized tip of ETT (solid arrow). AI also identified tracheal carina with probability score of 0.99 and properly localized carina (open arrow). Based on pixel spacing information in DICOM data header, AI automatically measured absolute distance between ETT tip and tracheal carina (tip-to-carina distance, TCD) as 4.3 cm. AI also measured distance between ETT tip and carina along radiograph’s vertical axis of (y-axis tip-to-carina difference, TCDy) as 4.0 cm, indicating that ETT tip is located 4.0 cm above carina. ETT is in proper position based on TCD. Right: Chest radiograph from 77-year-old patient in sample A. ETT is in critical position, with tip located below tracheal carina. AI-derived TCD was 2.5 cm. AI-derived TCDy was -1.4 cm, indicating that ETT tip is located 1.4 cm below carina. Image courtesy of AJR 


September 18, 2023 — According to an accepted manuscript published in the American Journal of Roentgenology (AJR), an artificial intelligence (AI) system developed by Lunit (Seoul, Korea) identified improperly positioned endotracheal tube (ETTs) on chest radiographs obtained after ETT insertion, as well as on chest radiographs obtained from patients in the ICU at two institutions. 

“Automated AI identification of improper ETT position on chest radiograph may allow earlier repositioning and thereby reduce complications,” wrote corresponding author Eui Jin Hwang, MD, PhD, from the department of radiology at Korea’s Seoul National University Hospital

Hwang et al.’s retrospective AJR study included 539 chest radiographs obtained immediately after ETT insertion from January 1, 2020 to March 31, 2020 in 505 patients (293 men, 212 women; mean age, 63 years) from institution A (sample A); 637 chest radiographs obtained from January 1, 2020 to January 3, 2020 in 304 patients (158 men, 147 women; mean age, 63 years) in the ICU (with or without an ETT) from institution A (sample B); and 546 chest radiographs obtained from January 1, 2020 to January 20, 2020 in 83 patients (54 men, 29 women; mean age, 70 years) in the ICU (with or without an ETT) from institution B (sample C). Lunit’s commercial DL-based AI system was used to identify ETT presence and measure ETT tip-to-carina distance (TCD). Reference standard for proper ETT position was TCD between 3 cm and 7 cm, determined by human readers. Critical ETT position was separately defined as ETT tip below the carina or TCD less than or equal to 1 cm. 

Ultimately, in three patient samples from two different institutions, an AI system identified ETT presence with sensitivity of 99.2–100%; and specificity of 94.5–98.7%, improper ETT position with sensitivity of 72.5–83.7% and specificity of 92.0–100%, and critical ETT position with sensitivity of 100% in all samples and specificity of 96.7–100%. 

For more information: www.arrs.org


Related Content

News | Innovative Hospitals

July 27, 2026 — Vanderbilt Health and Siemens Healthineers have entered into a multi-year, $87 million Value ...

Time July 28, 2026
arrow
News | Computed Tomography (CT)

July 23, 2026 — HOPPR has introduced HOPPR EF Chest CT Narrative Model, a foundation model that processes 3D chest CT ...

Time July 27, 2026
arrow
News | Pediatric Imaging

July 17, 2026 — In June, UW Health Kids began welcoming patients into a new state-of-the-art imaging suite dedicated to ...

Time July 23, 2026
arrow
News | Information Technology

July 20, 2026 — GE HealthCare has introduced MIM Anyware, a remote access platform that provides secure, healthcare ...

Time July 20, 2026
arrow
News | Radiation Oncology

July 16, 2026 — Raidium has announced the U.S. launch of Raidium Read (R.Read), applying its AI-native imaging solution ...

Time July 16, 2026
arrow
Feature | Information Technology | Kyle Hardner

Artificial intelligence (AI) has enhanced diagnostic accuracy and improved triage in radiology. But far fewer tools ...

Time July 16, 2026
arrow
News | ACR

July 15, 2026 — The American College of Radiology (ACR) recently issued a statement praising the inclusion of the ...

Time July 16, 2026
arrow
News | Cardiac Imaging

July 8, 2026 — Conavi Medical Corp. has announced the publication of a case report in the Journal of the Society for ...

Time July 15, 2026
arrow
News | PET Imaging

July 14, 2026 — New research is shedding new light on the biological basis of schizophrenia by directly measuring ...

Time July 15, 2026
arrow
News | Ultrasound Imaging

July 7, 2026 — Longeviti Neuro Solutions has launched a new strategic initiative, ClearFit AI, a Brain Ultrasound ...

Time July 09, 2026
arrow
Subscribe Now