News | Computed Tomography (CT) | August 15, 2022

Combo of deep-learning reconstruction and subtraction technique yielded optimal diagnostic performance for the detection of in-stent restenosis by coronary CTA 

57-year-old man who underwent coronary CTA using two-breath-hold subtraction technique to assess patency of coronary artery stent.

A. Conventional HIR image and B. conventional DLR image show blurred appearance of proximal aspect of stent (arrow). C. Subtraction HIR image and D. subtraction DLR image show discrete region of hypoattenuation at proximal aspect of stent (arrow). Both readers provided a diagnosis of in-stent restenosis only for subtraction HIR and subtraction DLR. Diagnostic confidence score for the four methods for reader 1 was 2, 2, 3, and 4, respectively, and for reader 2 was 1, 2, 3, and 3, respectively. Patient subsequently underwent invasive catheter angiography. Fluoroscopic imagines obtained (E) before and (F) after contrast media injection demonstrate in-stent restenosis of proximal aspect of stent (arrow). Image courtesy of ARRS and AJR 


August 15, 2022 — According to ARRS’ American Journal of Roentgenology (AJR), the combination of deep-learning reconstruction (DLR) and a subtraction technique yielded optimal diagnostic performance for the detection of in-stent restenosis by coronary CTA. 

Noting that these findings could guide patient selection for invasive coronary stent evaluation, combining DLR with a two-breath-hold subtraction technique “may help overcome challenges related to stent-related blooming artifact,” added corresponding author Yi-Ning Wang from the State Key Laboratory of Complex Severe and Rare Diseases at China’s Peking Union Medical College Hospital. 

Between March 2020 and August 2021, Wang and team studied 30 patients (22 men, 8 women; mean age, 63.6 years) with a total of 59 coronary stents who underwent coronary CTA using the two-breath-hold technique (i.e., noncontrast and contrast-enhanced acquisitions). Conventional and subtraction images were reconstructed for hybrid iterative reconstruction (HIR) and DLR, while maximum visible in-stent lumen diameter was measured. Two readers independently evaluated images for in-stent restenosis (≥50% stenosis). 

Ultimately, coronary CTA using DLR and subtraction technique—with a combined (conventional and subtraction images) interpretation—yielded PPV, NPV, and accuracy for in-stent restenosis for reader 1 of 73.3%, 93.2%, and 88.1%, and for reader 2 of 75.0%, 84.3%, and 83.1%, respectively. 

Acknowledging that the two-breath-hold subtraction technique requires an additional noncontrast acquisition (and thus a higher radiation dose), “DLR allows a reduction in radiation exposure, while improving image quality,” the authors of this AJR article pointed out

For more information: www.arrs.org 


Related Content

News | Pediatric Imaging

May 2, 2024 — Head and abdominal trauma is a leading cause of death for children. About 1%–2% of children who come to ...

Time May 02, 2024
arrow
Feature | Radiology Business

Beginning this spring, ITN will begin sending out a bi-monthly survey to our readers on a variety of topics, which we ...

Time May 02, 2024
arrow
News | Ultrasound Imaging

April 30, 2024 — Best Nomos, a TeamBest Global Company, is launching its most modern, highly innovative Compact SONALIS ...

Time April 30, 2024
arrow
News | Enterprise Imaging

April 25, 2024 — International medical imaging IT and cybersecurity company Sectra has signed two contracts to provide ...

Time April 25, 2024
arrow
News | Radiology Business

April 23, 2024 — A diverse writing group, led by authors at the University of Toronto, have developed an approach for ...

Time April 23, 2024
arrow
News | Computed Tomography (CT)

April 22, 2024 — A new study showed that a non-invasive imaging test can help identify patients with coronary artery ...

Time April 22, 2024
arrow
News | Clinical Trials

April 16, 2024 — QT Imaging Holdings, Inc., a medical device company engaged in research, development, and ...

Time April 16, 2024
arrow
News | Mammography

April 12, 2024 — Bayer and Hologic, Inc. announced a first-of-its-kind collaboration to deliver a coordinated solution ...

Time April 12, 2024
arrow
News | Mammography

April 12, 2024 — GE HealthCare, a leader in breast health technology and diagnostics, will feature its latest breast ...

Time April 12, 2024
arrow
News | Magnetic Resonance Imaging (MRI)

April 5, 2024 — Osteoarthritis — not age — may play the greatest role in determining the utility of MRI for patients 45 ...

Time April 05, 2024
arrow
Subscribe Now