Feature | March 25, 2014

UC Davis Papers Advocate New CT Dose Management Strategies

CT scan, radiation dose management, UC Davis
March 25, 2014 – UC Davis clinicians and physicists have recommended new strategies to make computed tomography (CT) safer, including adoption of a new metric for dose measurement, ways to manage exposure protocols that differ by CT brand and specific approaches to reduce exposure during needle biopsies. The recommendations are detailed in papers published in the March issue of the Journal of the American College of Radiology (JACR).
 
In response to concerns about the radiation dose in CT, JACR devoted the entire issue to CT safety. The federal government estimates that more than 80 million CT scans are performed in the United States each year. UC Davis specialists contributed three studies to the special issue.
 
CT is a powerful diagnostic technology that images organs and other internal structures. These scans can both detect life-threatening conditions and rule them out, giving clinicians precise information to develop a care plan. But there are risks. Ionizing radiation can damage cells and has been found to be a weak carcinogen. The challenge for radiologists and medical physicists is to find the optimal dosage for each CT exam.
 
“The higher the dose, the better the images,” said John Boone, vice chair of research in the department of radiology. “But you also want the lowest possible doses. So you need to find that balance between acceptable image quality and acceptable dosage.”
 
In the paper “Dose is Not Always What it Seems” Anthony Seibert, professor of radiology, and his colleagues discuss the need to improve dose calculations. They point to an actual case in which a pediatric patient who had scans before and after surgery appeared to receive an overdose on the second CT. Further investigation showed that the problem was a misleading metric — the volume CT dose index (CTDIvol), a standard measure of radiation output in CT. Manufacturers use phantoms along with instruments that measure radiation to assess CTDIvol. However, different companies use phantoms of different sizes. In addition, many dose estimates are based on adult sizes, making pediatric estimates more difficult.
 
“In this case, the difference was the way the manufacturers handled the metrics,” said Seibert. “A large phantom tends to underestimate dose, while a small phantom tends to overestimate it. When we compensated for the different-sized phantoms, it turned out the patient received almost the same dose in both scans.”
 
To help prevent future problems, the team recommended a new metric, size-specific dose estimate (SSDE), which provides a better way to measure patient dose and can also help compare scanners from different companies. It also addresses the dire need to more accurately estimate doses from CT across a range of patient sizes, from newborn to NFL linebacker.
 
“I think SSDE is one step closer to a dose metric that will be more accurate in depicting the actual risk to patients,” said Seibert.
 
This is not the only area where differences between scanners can obscure dosage. In another paper, “Methods for CT Automatic Exposure,” Boone, Seibert and colleagues addressed the challenges of optimizing different machines.
 
Physicists and radiologists must set up automatic exposure protocols, which vary doses based on tissue thickness. However, since manufacturers use different methods to control doses, transferring these settings between machines can be difficult and time-consuming.
 
“It takes a lot of effort to optimize any given scanner,” said Boone. “Going through the procedures for every possible exam could take two years.”
 
To ease the way, the UC Davis team developed equations to translate settings among three machines, two made by GE and one by Siemens. The proposed approach provides a more efficient way to manage CT protocols between different CT scanners.
 
A third paper, “Radiation Dose Optimization for CT-Guided Interventional Procedures” outlines how practitioners can lower radiation doses while performing interventional procedures under CT guidance. CT is often used to guide these procedures, ensuring the needle is precisely located.
 
Ramit Lamba, director of CT, outlines a number of methods to reduce radiation doses for both patients and doctors performing the procedures. He recommends using ultrasound, instead of CT, to guide some biopsies. He also recommends reducing scan lengths, lowering the tube current using dose-efficient scanning modes and limiting the number of guidance scans.
 
The special JACR issue is one piece of an ongoing effort to reduce CT risks. As part of the University of California Dose Optimization and Standardization Endeavor (UCDOSE), all five UC medical centers are collaborating to improve CT protocols and education.
 
“We’re trying to educate radiologists and medical physicists because the practice of CT is not consistent,” said Boone. “If someone is using higher doses to get results they could obtain with less radiation, we need to help them find the safer alternative.”
 
Other researchers included Rebecca Smith-Bindman of UC San Francisco; Sarah E. McKenney, formerly of UC Davis; and Sandra L. Wootton-Gorges of UC Davis. UCDOSE is funded through a pilot grant from the University of California Office of the President.
 
For more information: http://cancer.ucdavis.edu
 

Related Content

SimonMed Deploys ClearRead CT Enterprise Wide
News | Computer-Aided Detection Software | September 17, 2018
September 17, 2018 — National outpatient physician radiology group SimonMed Imaging has selected Riverain Technologie
Siemens Healthineers Announces First U.S. Install of Somatom go.Top CT
News | Computed Tomography (CT) | September 17, 2018
September 17, 2018 — The Ohio State University Wexner Medical Center in Columbus recently became the first healthcare
Sponsored Content | Whitepapers | Radiation Dose Management | September 10, 2018
It’s crucial for medical professionals to understand the radiation risk/ benefit balance of diagnostic imaging system
The CT scanner might not come with protocols that are adequate for each hospital situation, so at Phoenix Children’s Hospital they designed their own protocols, said Dianna Bardo, M.D., director of body MR and co-director of the 3D Innovation Lab at Phoenix Children’s.

The CT scanner might not come with protocols that are adequate for each hospital situation, so at Phoenix Children’s Hospital they designed their own protocols, said Dianna Bardo, M.D., director of body MR and co-director of the 3D Innovation Lab at Phoenix Children’s.

Sponsored Content | Case Study | Radiation Dose Management | September 07, 2018
Radiation dose management is central to child patient safety. Medical imaging plays an increasing role in the accurate...
Carestream Releases Second-Generation Metal Artifact Reduction Software for OnSight 3D Extremity System
Technology | Computed Tomography (CT) | September 06, 2018
Carestream Health has started shipping a new software version for its Carestream OnSight 3D Extremity System that...

Image courtesy of Medic Vision

Feature | Radiation Dose Management | September 06, 2018 | By Mukul Mehra, M.D.
While working with a patient with Crohn’s disease in my gastroenterology practice, I nearly ordered a computed...

Image courtesy of Siemens Healthineers

Feature | CT Angiography (CTA) | September 06, 2018 | Dave Fornell
There have been a few big, recent advancements in cardiac computed tomography angiography (CCTA) imaging technology....
Key Patient Preparations for a CT Scan
News | Computed Tomography (CT) | September 05, 2018
The Center for Diagnostic Imaging (CDI) in Miami recently released a list of important preparations patients should...
iSchemaView RAPID Technology Now Installed in More Than 500 Stroke Centers
News | Neuro Imaging | August 27, 2018
iSchemaView announced that more than 575 stroke centers in 22 countries have selected the RAPID advanced imaging...
Doctor-Patient Discussions Neglect Potential Harms of Lung Cancer Screening
News | Lung Cancer | August 15, 2018
August 15, 2018 — Although national guidelines advise doctors to discuss the benefits and harms of...