News | Computed Tomography (CT) | December 15, 2022

AJR guides optimization of clinical protocols when implementing ultra-high-resolution photon-counting detector (UHR PCD) CT of the lungs, providing insights on the association of reconstruction kernel and slice thickness with image quality.

61-year-old male, post lung transplant, who underwent photon-counting detector CT of chest in ultra-high-resolution mode. Reconstructions were performed at 0.2-mm slice thickness with BI56 kernel (A), BI60 kernel (B), and BI64 kernel (C); at 0.4-mm slice thickness with BI56 kernel (D), BI60 kernel (E), and BI64 kernel (F); and at 1.0-mm slice thickness with BI56 kernel (G), BI60 kernel (H), and BI64 kernel (I). Clinical-reference reconstruction (BI64 kernel at 1.0-mm slice thickness) is shown with red outli

61-year-old male, post lung transplant, who underwent photon-counting detector CT of chest in ultra-high-resolution mode. Reconstructions were performed at 0.2-mm slice thickness with BI56 kernel (A), BI60 kernel (B), and BI64 kernel (C); at 0.4-mm slice thickness with BI56 kernel (D), BI60 kernel (E), and BI64 kernel (F); and at 1.0-mm slice thickness with BI56 kernel (G), BI60 kernel (H), and BI64 kernel (I). Clinical-reference reconstruction (BI64 kernel at 1.0-mm slice thickness) is shown with red outline in lower right (I). Small bronchus with wall discontinuity, corresponding to origin of bronchial division, is well visualized on reconstructions at 0.2-mm and 0.4-mm slice thickness with Bl60 and Bl64 kernels (arrows), but not on clinical-reference reconstruction. All images displayed with window of -400 HU and level of 1400 HU.


December 15, 2022 —  An accepted manuscript published in ARRS’ American Journal of Roentgenology (AJR) guides optimization of clinical protocols when implementing ultra-high-resolution photon-counting detector (UHR PCD) CT of the lungs, providing insights on the association of reconstruction kernel and slice thickness with image quality.

Evaluating the impact of kernel and slice thickness on image quality of UHR PCD CT of the lungs using a 1024x1024 matrix, “the sharpest evaluated kernel, BI64, was the optimal kernel, consistent with the current clinical-reference technique,” wrote corresponding author Helmut Prosch from the department of biomedical imaging and image-guided therapy at the Medical University of Vienna in Austria.

In this AJR accepted manuscript, 29 patients (17 women, 12 men; median age, 56 years) underwent noncontrast chest CT using a first-generation PCD scanner (NAEOTOM Alpha, Siemens Healthineers, Forchheim, Germany) from February 15 to March 15, 2022. All acquisitions used UHR mode. Nine image sets were reconstructed for all combinations of three sharp kernels (BI56, BI60, BI64) and three slice thicknesses (0.2, 0.4, 1.0 mm). Three radiologists independently reviewed reconstructions for measures of visualization of pulmonary anatomic structures and pathologies using clinical-reference: BI641.0-mm.

Ultimately, when performing PCD CT of the lungs in UHR mode, reconstruction using BI64 kernel and 0.4-mm slice thickness was the only assessed reconstruction to yield improved bronchial division identification and bronchial wall and pulmonary fissure sharpness, without loss in pulmonary vessel sharpness or conspicuity of nodules or other pathologies.

In comparison, a 0.2-mm slice thickness—the thinnest reconstruction possible—was “associated with decreased visualization of various anatomic and pathologic findings,” the authors of this AJR accepted manuscript added.

For more information: www.arrs.org


Related Content

News | Cardiac Imaging

May 17, 2024 — The Cum Laude Award-Winning Online Poster presented during the 124th ARRS Annual Meeting found that the ...

Time May 17, 2024
arrow
News | Artificial Intelligence

May 15, 2024 — Heart disease is the leading cause of mortality in the U.S., accounting for one out of every five deaths ...

Time May 15, 2024
arrow
News | Pediatric Imaging

May 15, 2024 — Transfer learning (TL) models trained on heterogeneous public datasets and fine-tuned using institutional ...

Time May 15, 2024
arrow
News | Radiology Business

May 14, 2024 — University Hospitals (UH) and Siemens Healthineers announce a 10-year strategic alliance that builds on ...

Time May 14, 2024
arrow
News | Breast Imaging

May 10, 2024 — According to the Summa Cum Laude Award-Winning Online Poster presented during the 124th ARRS Annual ...

Time May 10, 2024
arrow
News | Radiation Oncology

May 10, 2024 — Insurance expansions under the Affordable Care Act (ACA) were linked with an increase in patients ...

Time May 10, 2024
arrow
News | Magnetic Resonance Imaging (MRI)

May 7, 2024 — The Magna Cum Laude Award-Winning Online Poster presented during the 124th ARRS Annual Meeting showed a ...

Time May 07, 2024
arrow
News | Treatment Planning

May 6, 2024 — Elekta announced the acquisition of Philips Healthcare’s Pinnacle Treatment Planning System (TPS) patent ...

Time May 06, 2024
arrow
News | Pediatric Imaging

May 2, 2024 — Head and abdominal trauma is a leading cause of death for children. About 1%–2% of children who come to ...

Time May 02, 2024
arrow
Feature | Radiology Business

Beginning this spring, ITN will begin sending out a bi-monthly survey to our readers on a variety of topics, which we ...

Time May 02, 2024
arrow
Subscribe Now