News | Artificial Intelligence | September 18, 2023

AI system by Lunit identified improperly positioned endotracheal tube on chest radiographs obtained after insertion, as well as on chest radiographs obtained from patients in the ICU at two institutions

AI system by Lunit identified improperly positioned endotracheal tube on chest radiographs obtained after insertion, as well as on chest radiographs obtained from patients in the ICU at two institutions

Left: Chest radiograph from 80-year-old patient in sample A. AI identified endotracheal tube (ETT) with probability score of 0.98, and properly localized tip of ETT (solid arrow). AI also identified tracheal carina with probability score of 0.99 and properly localized carina (open arrow). Based on pixel spacing information in DICOM data header, AI automatically measured absolute distance between ETT tip and tracheal carina (tip-to-carina distance, TCD) as 4.3 cm. AI also measured distance between ETT tip and carina along radiograph’s vertical axis of (y-axis tip-to-carina difference, TCDy) as 4.0 cm, indicating that ETT tip is located 4.0 cm above carina. ETT is in proper position based on TCD. Right: Chest radiograph from 77-year-old patient in sample A. ETT is in critical position, with tip located below tracheal carina. AI-derived TCD was 2.5 cm. AI-derived TCDy was -1.4 cm, indicating that ETT tip is located 1.4 cm below carina. Image courtesy of AJR 


September 18, 2023 — According to an accepted manuscript published in the American Journal of Roentgenology (AJR), an artificial intelligence (AI) system developed by Lunit (Seoul, Korea) identified improperly positioned endotracheal tube (ETTs) on chest radiographs obtained after ETT insertion, as well as on chest radiographs obtained from patients in the ICU at two institutions. 

“Automated AI identification of improper ETT position on chest radiograph may allow earlier repositioning and thereby reduce complications,” wrote corresponding author Eui Jin Hwang, MD, PhD, from the department of radiology at Korea’s Seoul National University Hospital

Hwang et al.’s retrospective AJR study included 539 chest radiographs obtained immediately after ETT insertion from January 1, 2020 to March 31, 2020 in 505 patients (293 men, 212 women; mean age, 63 years) from institution A (sample A); 637 chest radiographs obtained from January 1, 2020 to January 3, 2020 in 304 patients (158 men, 147 women; mean age, 63 years) in the ICU (with or without an ETT) from institution A (sample B); and 546 chest radiographs obtained from January 1, 2020 to January 20, 2020 in 83 patients (54 men, 29 women; mean age, 70 years) in the ICU (with or without an ETT) from institution B (sample C). Lunit’s commercial DL-based AI system was used to identify ETT presence and measure ETT tip-to-carina distance (TCD). Reference standard for proper ETT position was TCD between 3 cm and 7 cm, determined by human readers. Critical ETT position was separately defined as ETT tip below the carina or TCD less than or equal to 1 cm. 

Ultimately, in three patient samples from two different institutions, an AI system identified ETT presence with sensitivity of 99.2–100%; and specificity of 94.5–98.7%, improper ETT position with sensitivity of 72.5–83.7% and specificity of 92.0–100%, and critical ETT position with sensitivity of 100% in all samples and specificity of 96.7–100%. 

For more information: www.arrs.org


Related Content

News | Lung Imaging

May 24, 2024 — Smokers who have small abnormalities on their CT scans that grow over time have a greater likelihood of ...

Time May 24, 2024
arrow
News | Radiology Business

May 22, 2024 — Medtronic has announced new preliminary data from the VERITAS clinical study using its ILLUMISITE ...

Time May 22, 2024
arrow
News | Artificial Intelligence

May 22, 2024 — Lunit, a provider of Artificial intelligence (AI)-powered solutions for cancer diagnostics and ...

Time May 22, 2024
arrow
News | Artificial Intelligence

May 21, 2024 — According to a newly-published study of nearly 5,000 screening mammograms interpreted by an FDA-approved ...

Time May 21, 2024
arrow
News | Point-of-Care Ultrasound (POCUS)

May 20, 2024 — Exo (pronounced “echo”), a medical imaging software and devices company, announced the release of Exo ...

Time May 20, 2024
arrow
News | Cardiac Imaging

May 17, 2024 — The Cum Laude Award-Winning Online Poster presented during the 124th ARRS Annual Meeting found that the ...

Time May 17, 2024
arrow
Sponsored Content | Case Study | Enterprise Imaging

Having the most efficient clinical workflows with enhanced diagnostic capabilities is a major goal for clinicians and ...

Time May 16, 2024
arrow
News | Pediatric Imaging

May 15, 2024 — Transfer learning (TL) models trained on heterogeneous public datasets and fine-tuned using institutional ...

Time May 15, 2024
arrow
News | Radiology Business

May 14, 2024 — University Hospitals (UH) and Siemens Healthineers announce a 10-year strategic alliance that builds on ...

Time May 14, 2024
arrow
News | Prostate Cancer

May 13, 2024 — Avenda Health, an AI healthcare company creating the future of personalized prostate cancer care, unveils ...

Time May 13, 2024
arrow
Subscribe Now