Blog | Greg Freiherr, Industry Consultant | May 01, 2014

Do We Have the Courage to Scan Gently?

"Any intelligent fool can make things bigger, more complex, and more violent. It takes a touch of genius — and a lot of courage — to move in the opposite direction." —Albert Einstein

 

We fear what we can’t see and what we don’t know. It’s why children don’t want to go into a dark, unfinished basement. It’s what makes scary movies what they are.

Radiation is like that. It’s invisible. And, while many of us would say we understand it, we really don’t. We know radiation is part of the electromagnetic spectrum and that X makes us more susceptible to cancer. But exactly how? And to what extent? Are some of us more vulnerable? If so, why? How much radiation increases the likelihood of cancer? Over what period? Beginning at what age?

Asking these questions is a good thing. Recognizing that we don’t have the answers is scary. That, too, is a good thing.

Manufacturers are building CT scanners now that are extraordinarily stingy in the dose of X radiation they deliver. But it’s going to take awhile to get these scanners diffused through the installed base. In the meantime, there is much we can do to cut patient dose.

The methods do not involve bigger, more powerful CT scanners and they are only marginally more complex. But they require effort — and courage — to put in place, courage because the accepted way to improve image quality during the last 100-plus years has been to turn the voltage up, not down.

In March, at the European Congress of Radiology, Professor Thomas Albrecht, M.D., from the Institut für Radiologie und Interventionelle Therapie Vivantes,  Klinikum Neukölln in Berlin, Germany, showed how low-voltage CT, enhanced with contrast media, could reduce patient radiation dose while actually improving contrast enhancement. Image quality improves because the iodine in the contrast media absorbs more X-rays. This occurs as the mean energy of the X-ray beam, due to every less voltage, gets closer to the k-edge of iodine, which is 33.2 keV.

High kVp protocols generate high photon energies. At 140 kVp, for example, the keV is 61.5. At 80 kVp , the keV is 43.7. The latter is much closer to the k-edge of iodine.

By shifting the mean energy of the X-ray beam closer to this k-edge, more X-rays are absorbed by the contrast medium, thereby improving image contrast. Meanwhile, the lower tube voltage produces fewer X-rays, exposing the patient to less ionizing radiation. The reduction in patient radiation dose is remarkable.

Going from 120 kVp to 100 kVp can cut patient radiation dose from between 20 and 50 percent. Reducing tube voltage to 80 kVp can cut dose by as much as 70 percent.

Unfortunately, it’s not just a matter of turning down the voltage. To maintain image quality, tube current must increase about 50 percent. The exact increase varies according to body area and the scanner.

Similarly, radiation dose reduction to the patient depends on such factors as body habitus and body area. For example, thin patients reap a greater dose reduction than the obese. And dose savings also are most pronounced in the chest.

Such personalization of the CT exam requires a thorough understanding of the underlying physics of CT, as well as the habitus of the patient. But the increased safety of the patient, as well as the improved image quality, seem worth the effort.

Related Content

Researchers Awarded 2018 Canon Medical Systems USA/RSNA Research Grants
News | Radiology Imaging | November 13, 2018
The Radiological Society of North America (RSNA) Research & Education (R&E) Foundation recently announced the...
The Fujifilm FCT Embrace CT System displayed for the first time at ASTRO 2018.
360 Photos | 360 View Photos | November 07, 2018
Fujifilm's first FDA-cleared compu...
MaxQ AI Receives FDA Clearance for Accipio Ix Intracranial Hemorrhage Platform
Technology | Artificial Intelligence | November 07, 2018
MaxQ AI announced that its Accipio Ix intracranial hemorrhage (ICH) detection software has received 510(k) clearance...
Charles Ananian, M.D.

Charles Ananian, M.D.

Sponsored Content | Case Study | Digital Radiography (DR) | November 07, 2018
Whether it’s a premature baby or a critically ill child, treating little patients is a huge responsibility.
GE Healthcare Discovery RF Gen 2 system displayed at ASTRO 2018. It is a dedicated computed tomography (CT) scanner for radiation oncology
360 Photos | 360 View Photos | November 07, 2018
This is the GE Healthcare Discovery RF Gen 2 system displayed at the ...
Results of the vertebrae-based analysis (383 vertebrae in 34 patients) for detection of BME.

Results of the vertebrae-based analysis (383 vertebrae in 34 patients) for detection of BME.

Sponsored Content | Case Study | Computed Tomography (CT) | November 06, 2018
The following is a summary of a study published in the
The NeuViz 16 Essence from Neusoft Medical Systems.

The NeuViz 16 Essence from Neusoft Medical Systems.

Feature | Computed Tomography (CT) | November 05, 2018 | By Melinda Taschetta-Millane
According to an industry mark...
Carestream Spotlights Healthcare IT and Imaging Systems at RSNA 2018
News | Information Technology | October 31, 2018
Carestream announced it will be displaying several imaging and healthcare information technology (IT) offerings at the...
IMRIS, Siemens Strengthen Collaboration in Hybrid OR Neurosurgical Market
News | Hybrid OR | October 24, 2018
IMRIS, Deerfield Imaging, in partnership with Siemens Healthineers, announced a strengthened collaboration to advance...
Fujifilm Unveils FCT Embrace CT System for Oncology
Technology | Computed Tomography (CT) | October 23, 2018
Fujifilm Medical Systems U.S.A. Inc. recently introduced the FCT Embrace computed tomography (CT) system. Powered by...