Feature | Treatment Planning | July 08, 2013 | Dave Fornell

An Introduction to Current Radiation Therapy Treatment Planning Systems

This article appeared as an introduction to a Comparison Chart on Treatment Planning Systems in the July/August 2013 issue.

Treatment Planning systems, RT planning software

This is a brief overview of the newest software systems available on the treatment planning systems market.

Treatment planning systems are at the heart of radiation therapy (RT) systems and the key to improved patient outcomes. Once image datasets are loaded and the tumors are identified, the systems develop a complex plan for each beam line route for how the therapy system will deliver radiation. The software also computes the expected dose distribution in the patient’s tissue, including variables such as tissue energy level penetration influences by the type of tissue the beam lines encounter (e.g., bone or lung vs. muscle). These systems also help navigate beam placement based on avoiding critical structures that are more sensitive to radiation in an effort to reduce collateral damage from the therapy. This may include automated, complex programming for multi-leaf collimator (MLC) leaf sequencing to shape the beam around critical structures during dose delivery. These treatment plans can also be modified to compensate for the reduction in tumor size over the course of treatments.

See the latest news and articles on treatment planning on the ITN Treatment Planning Channel page. 
 

Access the most current version of the ITN Treatment Planning Systems Comparison Chart (www.itnonline.com/content/treatment-planning-systems). This will require a login, but it is free and only takes a minute to complete the form.
 

Brainlab

Brainlab’s iPlan RT treatment planning offers efficient clinical workflows and provides more treatment options for clinicians to choose from. Its image features offer time-saving pre-planning steps, such as automatic image fusion and fast organ definition and contouring. The software caters to a wide spectrum of treatment techniques to help define the best possible treatment plan. The Brainlab Monte Carlo Dose Calculation software is a high-performance algorithm designed for fast, precise radiation therapy dose calculations. Brainlab technology currently powers treatments in the fields of neurosurgery, radiation oncology, orthopedics, ENT, CMF, spine and trauma. 

Elekta

XiO is a comprehensive 3-D intensity modulated radiation therapy (IMRT) treatment planning platform that combines advanced planning tools with robust dose calculation algorithms. It supports a range of treatment modalities, including 2-D, 3-D, MLC-based IMRT, solid compensator-based IMRT and brachytherapy. In addition, dynamic conformal arc therapy and stereotactic delivery are supported.

XiO offers advanced dose calculation algorithms, including Clarkson, FFT Convolution, MultiGrid Superposition, Fast Superposition and Electron Monte Carlo. Clinicians can choose the algorithm that is most appropriate for each plan. The software helps simplify planning with user-definable templates, calculation grids and workspace.

Elekta’s Monaco system offers treatment planning for IMRT, volumetric modulated arc therapy (VMAT) and stereotactic body radiation therapy (SBRT). Monaco features innovative biological cost functions with multi-criteria constrained optimization, a leaf sequence optimizer and a robust Monte Carlo dose calculation algorithm.

Philips

Pinnacle³ is designed for small and mid-size centers as an affordable server-class system that provides access from virtually any location. The system is also scalable so it can grow with a center’s needs. It can support centers with up to three linear accelerators (LINACs). Centralized processing offers all users the power of the professional server.

The system is up to 30 percent faster than the older 810X platform. Floating licenses allow a Pinnacle³ user to have unlimited number of access points, including MacIntosh users.

Prowess

The Panther 3D Conformal Therapy system is designed to improve efficiency. It operates on the user-friendly Windows platform, allowing the fast generation of treatment plans due to the familiar Windows look and feel and the vendor’s intuitive user interface. The system is completely modular to make upgrades with new modules easy and seamless.

Panther supports Siemens virtual wedges, and photon and electron beams can be combined. It offers MLC support, and the MLC display can be turned on or off. MLC can auto fit to any selected organ with a specified margin, including inner, outer or center edges. Individual MLC leafs also can be graphically edited. 

RaySearch

Previously an OEM for treatment planning systems offered by other vendors, RayStation has created its own RaySearch proprietary system. It incorporates optimization application tools that have been in operation for nearly 10 years. The core of the system is the ORBIT software framework, which is currently used by some 2,000 clinics all over the world for optimization of IMRT, VMAT and 3-D conformal radiotherapy (3-DCRT).

RayStation has been designed for 4-D adaptive radiation therapy as a built-in generic feature and it incorporates the latest techniques for proton therapy. It also contains tools for multi-criteria optimization, enabling a much more intuitive treatment planning process. The software uses a modular design to offer different combinations of capabilities. 

RayStation’s proton features are pending regulatory approvals and have not been cleared for marketing outside of the European Union.  

Varian

The Eclipse system allows for efficiency. Virtual simulation eliminates data transfer steps and the management of separate sets of data. Emergency treatments can be planned immediately in the simulation area.

Powerful tools simplify contouring tasks and field setup, and a fast calculation engine reduces treatment planning time. Integrated plan verification and quality assurance tools speed ongoing treatment planning and beam data validation, saving time for physicists. For example, with the portal dosimetry option, the physics time required for IMRT pretreatment verification is reduced to less than 20 minutes per patient compared to hours with film. High-resolution IMRT treatments can typically be delivered in a normal 15-minute time slot on a Varian Clinac linear accelerator. 

Related Content

Drug Accelerates Blood System's Recovery After Radiation, Chemotherapy

Following radiation, the bone marrow shows nearly complete loss of blood cells in mice (left). Mice treated with the PTP-sigma inhibitor displayed rapid recovery of blood cells (purple, right). Credit: UCLA Broad Stem Cell Research Center/Nature Communications

News | Radiation Therapy | August 16, 2019
A drug developed by UCLA physician-scientists and chemists speeds up the regeneration of mouse and human blood stem...
Mevion and C-RAD Release Integration for Improved Proton Therapy Treatment Quality

Catalyst PT image courtesy of C-RAD

News | Patient Positioning Radiation Therapy | August 15, 2019
Mevion Medical Systems and C-RAD announced the integration between the C-RAD Catalyst PT and the Mevion S250i proton...
First Patient Enrolled in World's Largest Brain Cancer Clinical Trial
News | Radiation Therapy | August 15, 2019
Henry Ford Cancer Institute is first-in-the-world to enroll a glioblastoma patient in the GBM AGILE Trial (Adaptive...
Efficacy of Isoray's Cesium Blu Showcased in Recent Studies
News | Brachytherapy Systems | August 14, 2019
August 14, 2019 — Isoray announced a trio of studies recently reported at scientific meetings and published in medica
MD Anderson to Expand Proton Therapy Center

The MD Anderson Proton Therapy Center expansion is expected to be completed in 2023. Rendering courtesy of Stantec.

News | Proton Therapy | August 08, 2019
The University of Texas MD Anderson Cancer Center unveiled plans to expand its Proton Therapy Center during a...
Qfix kVue One Proton Couch Top Validated by Mevion Medical Systems
News | Patient Positioning Radiation Therapy | August 07, 2019
Qfix and Mevion Medical Systems announced that a special version of the kVue One Proton couch top is now both validated...
IBA Signs Contract to Install Proton Therapy Center in Kansas
News | Proton Therapy | August 06, 2019
IBA (Ion Beam Applications S.A.) recently signed a contract and received the first payment for a Proteus One solution...
The top piece of content in July was a video interview explaining how Princess Margaret Cancer Center is using machine learning to create automated treatment plans. This was a hot topic at the American Association of Physicists in Medicine (AAPM) 2019 meeting in July.

The top piece of content in July was a video interview explaining how Princess Margaret Cancer Center is using machine learning to create automated treatment plans. This was a hot topic at the American Association of Physicists in Medicine (AAPM) 2019 meeting in July. 

Feature | August 05, 2019 | Dave Fornell, Editor
August 5, 2019 — Here is the list of the most popular content on the Imaging Technology New (ITN) magazine website fr
Varian Showcases Cancer Care Systems and Software at AAPM 2019
News | Radiation Therapy | August 02, 2019
Varian showcased systems and software from its cancer care portfolio, including the Identify Guidance System, at the...
Laura Dawson, M.D., FASTRO, Chosen as ASTRO President-elect
News | Radiation Oncology | July 31, 2019
The members of the American Society for Radiation Oncology (ASTRO) elected four new officers to ASTRO’s Board of...