Technology | Mammography | November 22, 2016

Sigmascreening to Introduce Sensitive Sigma Paddle at RSNA 2016

Device has multiple sensors to measure breast size and tissue stiffness for personalized compression during mammography

Sigmascreening, Sensitive Sigma Paddle, mammography, compression, RSNA 2016

November 22, 2016 — Sigmascreening will introduce the Sensitive Sigma Paddle at the upcoming 102nd Annual Radiological Society of North America (RSNA) meeting, Nov. 27-Dec. 2 in Chicago. The Sensitive Sigma Paddle enables personalized compression for better quality mammograms without unnecessary discomfort for patients.

Each year, an estimated 125 million women throughout the world are imaged using mammography. To get the best image quality during a mammogram with the least amount of radiation, the breast needs to be flattened. This is done by compressing the breast. Under-compression can lead to blurred images, more retakes and a higher average glandular dose (AGD), while over-compression causes discomfort and unnecessary pain for the patient. British research estimates that up to 20 percent of screening-eligible women worldwide decide not to have a mammogram because of the pain. This can decrease the rate of early detection, and delay medical treatment of tumors, thus decreasing women's chances of survival.

The patented Sensitive Sigma Paddle has multiple sensors that measure each breast to optimize compression for each breast. Based on breast size and tissue stiffness, the device calculates the pressure to achieve an optimal compression of 75mmHg and allows for a highly reproducible procedure. Sigmascreening said the Sensitive Sigma Paddle is the first pressure-based compression paddle in the market which provides this pressure information real-time.

Investigational in the United States, the device is CE-marked and is actively being used at breast screening centers and hospitals in England, Germany, Sweden, The Netherlands, Belgium and Switzerland since receiving CE-mark last year.

The relationship between pressure applied during compression of the breast and screening performance was recently investigated in the study “Performance of breast screening and cancer detection depends on mammography compression,” which was presented at the 13th International Workshop of Mammographic Imaging in Malmö, June 2016, and published in Breast Imaging. Researchers computed the compression pressure applied to a series of 113,464 screening mammograms. Screening performance measures were determined for each group. Results demonstrated that compression pressures that are too low lead to a higher recall rate and false positives, and compression pressures that are too high reduce detectability of breast cancer. Cancer detection rate and the positive predictive value were optimal in the middle compression category.

For more information: www.sigmascreening.com

Related Content

Fujifilm Announces Nationwide Breast Health Campaign With Mobile Mammography Coach

At the center of the campaign, Fujifilm will be traveling around the U.S. with its "Aspire to Be Fearless" mobile mammography coach to provide educational opportunities for clinicians, raise awareness about the importance of screening and will be providing mammograms to the underserved population in key locations.

News | Mammography | June 14, 2019
Fujifilm Medical Systems U.S.A. Inc. announced a nationwide awareness campaign titled ‘Aspire to Be Fearless’ focused...
Ikonopedia Showcases Risk Assessment and Resolution Manager Tools at SIIM and AHRA
News | Mammography Reporting Software | June 13, 2019
Ikonopedia will showcase its suite of structured breast reporting and Mammography Quality Standards Act (MQSA)...
Sponsored Content | Videos | Radiology Imaging | June 13, 2019
In an interview with itnTV, Henry Izawa, vice president, modality solutions and clinical affairs, Fujifilm Medical Sy
iCAD Introduces ProFound AI for 2D Mammography in Europe
News | Artificial Intelligence | June 13, 2019
iCAD Inc. announced the launch of ProFound AI for 2D Mammography in Europe. This software is the latest addition to...
Three Palm Software Releases WorkstationOne Version 1.8.8
Technology | Mammography Reporting Software | June 12, 2019
Three Palm Software announced the release of the 1.8.8 version of its breast imaging workstation, WorkstationOne. This...
Volpara Health Technologies to Acquire MRS Systems Inc.
News | Mammography Reporting Software | June 04, 2019
Volpara Health Technologies, Volpara Solutions' parent company, has signed a binding agreement to acquire U.S.-based...
62-year-old female patient presenting for 3D screening mammogram. Location of an indeterminate low-density circumscribed mass was not clearly determined as at the skin line or just under the surface.

62-year-old female patient presenting for 3D screening mammogram. Location of an indeterminate low-density circumscribed mass was not clearly determined as at the skin line or just under the surface.

Feature | Mammography | May 31, 2019 | By Olive Peart M.S., R.T.(R)(M)
In recent years there has been a lot of debate about the role of the...
Quantitative Transmission Ultrasound Featured at Acoustical Society of America

Fused QT Ultrasound 3-D quantitative transmission ultrasound and compounded reflection axial images showing high resolution image of internal organs, tissue, skin and hair of neo-natal piglet. Anatomy courtesy of C. Ruoff, DVM.

News | Ultrasound Imaging | May 29, 2019
May 29, 2019 — QT Ultrasound recently showcased its advanced...
VolparaDensity With Tyrer-Cuzick Model Improves Breast Cancer Risk Stratification
News | Breast Density | May 22, 2019
Research has demonstrated use of Volpara Solutions' VolparaDensity software in combination with the Tyrer-Cuzick Breast...
Partial Breast Irradiation Effective, Convenient Treatment Option for Low-Risk Breast Cancer
News | Radiation Therapy | May 20, 2019
Partial breast irradiation produces similar long-term survival rates and risk for recurrence compared with whole breast...