Feature | May 04, 2015 | Dave Fornell

New Advances in PET/CT Technology

This article appeared as an introduction to a Comparison Chart on PET/CT Systems in the May 2015 issue.

There have been several technology advances in PET/CT (positron emission tomography/computed tomography) systems recently introduced by vendors. On the show floors of the 2014 Society of Nuclear Medicine and Molecular Imaging (SNMMI) meeting and the 2014 Radiological Society of North America (RSNA) meeting, Philips, Toshiba and GE Healthcare introduced new PET/CT systems. You can view the PET/CT Systems comparison chart here.

Philips Vereos First to Offer Digital Detectors

The Philips Vereos is the first PET/CT on the market to offer digital PET detectors, allowing improved image clarity over traditional analog photomultipliers.  The system was first unveiled at RSNA 2013. It uses Philips’ digital photon counting technology in its digital silicon detectors. Philips said this results in a step change in performance that approximately doubles sensitivity gain, volumetric resolution and quantitative accuracy compared to analog systems. These radical improvements can ultimately be translated into high image quality, increased diagnostic confidence, improved treatment planning and faster workflows.

Toshiba’s Celesteion

Toshiba showed its first entry into the molecular imaging market when it unveiled its Celesteion PET/CT. The company hopes to attract buyers with what it describes as the industry’s largest bore, widest field-of-view, dose reduction technology and fast imaging. The bore is 90 cm for CT, 88 cm for PET. Field-of-view is 70 cm for both CT and PET, with an 85 cm CT extended FOV. Dose is minimized through Toshiba’s adaptive iterative dose reduction and Celesteion’s compliance with the Medical Imaging and Technology Alliance’s XR-29 Smart Dose Standard. The new PET/CT offers time-of-flight resolution and 0.5 sec CT rotation with 0.5 mm slices across a 32-slice detector.

Discover IQ

In addition, GE Healthcare introduced its Discovery IQ PET/CT system, which became U.S. Food and Drug Administration (FDA) cleared in September. It enables both high image quality and intelligent quantitation. GE said it delivers the highest NEMA (National Electrical Manufacturers Association) sensitivity (up to 22 cps/kBq) and the largest axial field-of-view (up to 26 cm) compared to other PET/CT equipment. 

GE’s new Q.Clear image reconstruction software is a big component of Discovery IQ, eliminating trade-offs between image quality and quantitative SUV measurements. By providing two times improvement in both quantitative accuracy (SUV mean) and image quality (SNR) in PET/CT imaging, this new tool provides benefits to physicians across the cancer care continuum from diagnosis and staging to treatment planning and assessment.  Over the last decade, PET image reconstruction technology has been designed to provide better image quality, reduced acquisition time and lower injected dose. Current PET iterative reconstruction technologies, such as time of flight (TOF) and ordered-subsets expectation maximization (OSEM), force a compromise between image quality and quantitation, GE said.  

The Discovery IQ uses GE’s new LightBurst detector technology, allowing for whole organ imaging via fast scans at low dose. It also uses fast electronics and a dual acquisition channel that enables high quantitative accuracy for all clinically relevant tracers.

The Discover IQ includes the CortexID software, which aids physicians in the evaluation of patient pathologies via assessment and quantification of PET brain scans. It enables automated analysis through quantification of tracer uptake and comparison with the corresponding tracer uptake in normal subjects. The resulting quantification is presented using volumes of interest, voxel-based or 3-D stereotactic surface projection maps of the brain. The package allows the user to generate information regarding relative changes in PET-FDG glucose metabolism and in PET brain amyloid load between a subject’s images and a normal database, which may be the result of brain neurodegeneration.

Siemens Continuous Motion Bed

In 2013, Siemens Healthcare introduced the Biograph mCT Flow PET/CT system that overcomes the limitations of conventional bed-based PET/CT. It uses Siemens’ FlowMotion technology that moves the patient smoothly through the system’s gantry while continuously acquiring PET data. FlowMotion expands quantification in all dimensions for precise disease characterization in therapy monitoring, while enabling physicians to offer as low as reasonably achievable (ALARA) dose to every patient. The scanner uses a 78 cm bore with five-minute scanning and a continuous sense of progress throughout the scan provides the patient with a more comfortable exam experience.

Conventional PET/CT suffers from intrinsic sensitivity degradation from the center to the edge of the axial FOV. Overlapping sequential bed positions are used to compensate for this constraint, but this approach can lead to axially varying noise sensitivity.  This noise can distort the quantitative values of a detected lesion, which may prompt a physician to mischaracterize the severity of a tumor. By continuously moving the patient through the detection system, FlowMotion technology eliminates overlapping bed acquisitions and maintains uniform noise sensitivity across the entire scan range.

Related Content

Phase III response to the COVID-19 public health emergency (PHE) CARES Act signed into law #CARESAct #COVID19 #Coronavirus #2019nCoV #Wuhanvirus #SARScov2
Feature | Coronavirus (COVID-19) | March 28, 2020 | By Melinda Taschetta-Millane
On March 27, the House of Representatives approved a historic $2
AI vendor Infervision's InferRead CT Pneumonia software uses artificial intelligence-assisted diagnosis to improve the overall efficiency of the radiology department. It is being developed in China as a high sensitivity detection aid for novel coronavirus pneumonia (COVID-19). #COVID19 #coronavirus #SARScov2

AI vendor Infervision's InferRead CT Pneumonia software uses artificial intelligence-assisted diagnosis to improve the overall efficiency of the radiology department. It is being developed in China as a high sensitivity detection aid for novel coronavirus pneumonia (COVID-19).

Feature | Coronavirus (COVID-19) | March 27, 2020 | Jilian Liu, M.D., HIMSS Greater China
An older couple walked into the Hubei Provincial Hospital of Integrated Chinese and Western Medicine near their neigh
#COVID19 #Coronavirus #2019nCoV #Wuhanvirus #SARScov2

Typical CT imaging features for COVID-19. Unenhanced, thin-section axial images of the lungs in a 52-year-old man with a positive RT-PCR (A-D) show bilateral, multifocal rounded (asterisks) and peripheral GGO (arrows) with superimposed interlobular septal thickening and visible intralobular lines (“crazy-paving”). Routine screening CT for diagnosis or exclusion of COVID-19 is currently not recommended by most professional organizations or the US Centers for Disease Control and Prevention. Image courtesy of RSNA

News | Coronavirus (COVID-19) | March 26, 2020
March 26, 2020 — The Radiological Society of North America (RSNA
Novel scanners may open door for prognostic assessment in patients receiving cochlear implants

Iva Speck, MD, explains research showing that novel, fully digital, high-resolution positron emission tomography/computed tomography imaging of small brain stem nuclei can provide clinicians with valuable information concerning the auditory pathway in patients with hearing impairment. The research is featured in The Journal of Nuclear Medicine (read more at http://jnm.snmjournals.org/content/current). Video courtesy of Iva Speck, University Hospital Freiburg, Germany.

News | PET-CT | March 26, 2020
March 26, 2020 — Novel, fully digital, high-resolution...
#COVID19 #Coronavirus #2019nCoV #Wuhanvirus #SARScov2
News | Coronavirus (COVID-19) | March 25, 2020
March 25, 2020 — According to a statement on March 24 from Commissioner of Food and Drugs - Food and Drug Administrat
#COVID19 #Coronavirus #2019nCoV #Wuhanvirus #SARScov2
News | Coronavirus (COVID-19) | March 24, 2020
March 24, 2020 — The U.S.
#COVID19 #Coronavirus #2019nCoV #Wuhanvirus #SARScov2

Representative examples of the attention heatmaps generated using Grad-CAM method for (a) COVID-19, (b) CAP, and (c) Non-Pneumonia. The heatmaps are standard Jet colormap and overlapped on the original image, the red color highlights the activation region associated with the predicted class. COVID-19 = coronavirus disease 2019, CAP = community acquired pneumonia. Image courtesy of the journal Radiology

News | Coronavirus (COVID-19) | March 20, 2020
March 20, 2020 — An arti...
#COVID19 #Coronavirus #2019nCoV #Wuhanvirus #SARScov2

Series CT scans in 35-year-old woman with COVID-19 pneumonia. (a) Scan obtained on illness days 1 showed multiple pure ground-glass opacity (GGO) mainly in right lower lobe. (b) Scan obtained on illness days 5 showed increased extent of GGO and early consolidation. (c) Scan obtained on illness days 11 showed multiple consolidation with almost the same extent. (d) Scan obtained on illness days 15 showed a mixed pattern with a slightly smaller extent, and the perilobular consolidation might suggest the presence of organizing pneumonia. The patient was discharged on illness days 17. Image courtesy of the journal Radiology

News | Coronavirus (COVID-19) | March 20, 2020
March 20, 2020 — In a new study pub